SUPER TTB
DESCRIPTION
Super TTB is a premium grade thick or thin bed
cement-based adhesive specifically formulated to
produce an extra high strength bond for the fixing of
tiles onto rigid substrates.
USES
Super TTB can be used on both walls and floors
in interior and exterior applications.
Super TTB can be used to fix tiles onto concrete
cement renders/screeds blockwork rendered
brickwork and particular waterproofing
membranes.
Super TTB is recommended for the thin or thick
bed fixing of all types of ceramic mosaic fully
vitrified porcelain terracotta slate quarry
granite and marble tiles with the exception of light
coloured or green marbles.
When using Super TTB with
translucent/absorbent tiles the colour of the
adhesive must be considered to avoid
discolouration problems.
Super TTB when combined with neat Davelastic
can be used to fix tiles over tiles onto facades or
fix tiles in immersed situations i.e. swimming
pools spas etc. Initially contact your ParexDavco
(Australia) Pty Ltd state office for further details.
SURFACE PREPARATION
All surfaces must be structurally sound dry clean
and free from movement oil grease wax curing
compounds and any other loose or contaminating
materials.
Painted surfaces must be scabbled/abraded to
expose at least 80% of the original substrate.
Newly rendered/screeded surfaces must be
allowed to cure for at least 7 days and have a
wood float finish.
Old rendered/screeded surfaces must be
thoroughly cleaned prior to tiling and have a wood
float finish.
New concrete must be allowed to cure for 6
weeks and should have a wood float finish.
Steel trowel finished concrete must be acid
etched or mechanically abraded prior to tiling.
Old concrete surfaces must be thoroughly
cleaned prior to tiling.
Make sure all release agents are removed from
concrete surfaces especially on tilt-up slabs.
Porous/dusty surfaces must initially be primed
using Davco Ultraprime.
Certain non-absorbent/contaminated surfaces can
easily be prepared for tiling via the use of Davco
Ultrabond.
Movement joints should be provided as follows:
1. Over movement joints in the background.
2. At a junction between different background
materials.
3. At fixtures interrupting the tile surface e.g.
columns.
4. At internal vertical corners.
5. Around the perimeter of the tiling system.
6. At a maximum of 5 metre intervals in a grid
pattern.
Note: Movement joints should go right through the tile
adhesive bed to the background and be kept free from
dirt and adhesive droppings. Movement joints must
not be less than 6mm nor greater than 10mm wide.
All movement joints that are 6mm wide can be filled
with Davco Sanitized® Colorcaulk. For wider
applications use Davco Davsil or polysulphide and
polyurethane type fillers.
MIXING
Add Super TTB to a bucket of clean water mixing
constantly until a thick creamy consistency is
achieved.
The mixing ratio is 20kg of Super TTB to
approximately 5 litres of clean water.
Allow the mixture to stand for 10 minutes remix
then use the adhesive.
APPLICATION
Spread the adhesive onto the substrate using a
6mm x 6mm notched trowel for the installation of
wall tiles up to 150mm x 150mm.
For the installation of floor tiles or wall tiles larger
than 150mm x 150mm use a 10mm x 10mm to a
12mm x 12mm notched trowel.
Tiles with lugs grooves or an uneven back must
initially be butter coated with the adhesive in
addition to the adhesive being trowelled onto the
substrate.
A 6mm x 6mm-notched trowel can be used to lay
mosaic tiles.
SUPER TTB
For wall tiling a minimum final bed thickness of
2mm is recommended whilst for floor tiling a
minimum final bed thickness of 3mm is
recommended.
Do not spread more than 1m2 of adhesive at any
one time.
Press tiles firmly into position before the adhesive
skins ensuring that all the tiles are well bedded
and that no voids occur under the tiles.
Occasionally in order to ensure that full coverage
is being maintained a tile should be removed the
adhesive coverage noted and the tile be relaid
accordingly.
Once the tiles have been laid they must not be
disturbed or trafficked upon for 24 hours at 20oC.
GROUTING
Grouting can be carried out 24 hours after the
completion of tiling.
Use the Davco grout that best suits the tiling
installation. Refer to the Davco Adhesive and
Grout Selection Guide for further information.
To enhance colour increase water resistance and
flexibility of the grout use Davco Grout Additive.
This is particularly recommended when grouting
over timber or fibre cement sheeted floors to
minimise the likelihood of the grout
cracking/powdering.
Allow 24 hours after grouting before putting the
area into service.
PRECAUTIONS
Do not apply Super TTB in temperatures above
400C or below 50C.
Do not allow the adhesive to skin prior to laying
the tiles. If the adhesive skins remove and
dispose of it then re-apply fresh adhesive.
For other uses or the use of Super TTB in
situations not mentioned in these instructions
contact your ParexDavco (Australia) Pty Ltd state
office
Being cement based Super TTB is alkali in
nature which can cause dermatitis. It is
recommended that applicators wear PVC or
similar gloves and safety goggles.
For a full MSDS on this product contact your
ParexDavco (Australia) Pty Ltd state office.
COVERAGE
A 20kg bag Super TTB will cover approximately 6m2
using a 6mm x 6mm notched trowel.
CLEAN UP
Remove any excess adhesive from the face of the
tiles with a damp cloth while the adhesive is still
wet.
Clean tools and equipment with water before the
adhesive dries.
PACKAGING
Super TTB is available in 20kg bags.
SHELF LIFE
Up to 12 months in unopened bags stored in an
elevated cool dry position.
TECHNICAL DATA
Properties:
Appearance: Grey Powder
Bulk Density: ~1.4 kg/litre
Open Time at 200C: 7 minutes
Adjustment Time at 20oC: 10 minutes
Pot Life at 20oC: 40 minutes
Drying Time at 200C: 24 hours
DISCLAIMER
The use of this product is beyond the manufacturers control and
liability is restricted to the replacement of material proven faulty. The
manufacturer is not responsible for any loss or damage arising from
incorrect usage. All workmanship must be carried out in accordance
with AS 3958.1 – 1991.
The information contained herein is to the best of our knowledge true
and accurate. No warranty is implied or given as to its completeness or
accuracy in describing the performance or suitability of the product for a
particular application. Users are asked to check that the literature in
their possession is the latest issue.
Reviews